2.3.3 FACTORY MUTUAL NI KIT
The Integra-TR with the Factory Mutual NI Kit (DRL part number 023-1000-200) is approved as non-incendive for Class I,
Groups ABCD, Division 2, hazardous locations by Factory Mutual Research Corporation. This option includes approval for
International Electrotechnical Commission (IEC) Class I, Zone 2.
Approved models are labeled with this rating. Only units with the Factory Mutual approved label carry the nonincendive
rating. Installation, service, and repair of the FM approved units must be in accordance with the instructions found in this
manual and the National Electrical Code (ANSI-NFPA 70) Division 2: Hazardous (classified) Location Incendive Wiring
Techniques. Mount the unit in an enclosure or assembly. Route all interconnecting cables (DC power and coaxial) through
conduit as specified in the National Electrical Code document referenced above. For further guidance on installation, see
ANSI\ISA-RPI2.6: Installation of Intrinsically Safe Systems for Hazardous (Classified) locations.