Table 12 - Normal Factory Settings (Bases)
Fields
Full Duplex Base Integra-TR with other
Integra-TR
Redundant Integra-TR Full Duplex
Base with Integra-TR/Integra-T
RX Unit
TX Unit
RX Units
TX Units
Network Settings
Station ID (CWID)
Disabled (OFF)
Compatibility Mode
Integra-TR
Integra-T / TR
Extended Preamble (ms)
5 mS
0 mS
Network Speed
19200 Full Channel 9600 Half Channel
2400 Quarter Channel
9600 Full Channel
Tx Online Diagnostics
Yes
Unit Type
Master
Data Delivery
All
Activity Time-out (sec)
5
COM Port
Device Baud
19200 / 9600 / 2400
9600
Data fwd timer
Normal
Parity
8 bit, no parity, 1 stop bit
Break
Ignore break
Xmit Control
DOX
DCD Control
Switched
External I/O Connector
I/O 1
Input Output
Fan Control
Input Output
Fan Control
I/O 2
RxTp
Input
RxTp
Ant. SW Control
Frequency
Transmit
User Choice
Receive
User Choice
Adjustments
Carrier Sense (-dBm)
105 (116 for
quarter-channel)
(N/A)
110
(N/A)
Tx Time Out
Disabled
Disable Tx w/Carrier Present
Disabled (OFF)
Tx Power
255 (indicates 5 watts nominal)
Transceiver Type
Rx Only
Tx Only
Rx Only
Tx Only