User's Manual

Page | 47
interfaced with will output Online Diagnostics as they are received. Using Online Diagnostics does not require suspension of
network operation.
Online Diagnostics are subject to alarm conditions defined in Section XXX Diagnostic IDs and Alarms. When Online
Diagnostics are received and a diagnostic field falls outside the alarm limits, value X will be designated as less than < or
greater than > the allowed parameters.
Figure 33: Online Diagnostics
The following Online Diagnostics are gathered:
Short ID
Displays the Short ID of the unit transmitting the diagnostics.
Temp
Displays the internal case temperature (in Celsius) of the unit transmitting the diagnostics.
Batt
Displays the supply voltage (in volts) of the unit transmitting the diagnostics.
Local RSSI
If these are the diagnostics from a Remote Station, Local RSSI indicates the RSSI level of the Local Station obtained
by the Remote Station transmitting these diagnostics. If these are the diagnostics from the Local Station, Local RSSI
indicates the RSSI level of the Local Station from the last transmission of a Remote Station.
FwdP
Displays the forward power (in watts) of the unit transmitting the diagnostics.