Technical Manual

Table Of Contents
120 20170-201 Paragon
PD
Technical Manual
30
6.1.3 File Creation
1. In WIN 3.x: Start by clicking on File, then on Run, type the path or browse to select the
Tait program, click OK to run PGM800Win executable program.
In WIN 9x: click on Start, then on Run, type the path or browse to select, click OK to run
PGM800Win.
2. In the Tait program’s Menu bar, click on “View”. On the drop-down menu, make sure
that a check mark is present in front of the “T800 EPROM” option. If not, click this op-
tion to activate it and click on “View” again to verify that a check mark is now present.
3. Select File, New and choose the relevant unit model to program. Click on OK. The pro-
gram displays a dual-tabbed virtual file folder.
4. Click the System Information tab; enter the unit’s serial number in the relevant field.
In the User Remarks field, you may enter user comments as required (up to 16 charac-
ters). Use as a notepad (customer name, location, technical info etc...). Refer to Figure
18.
Click the Channel Information tab; click the relevant frequency field to make it active
and type in the required channel number in the frequency field. Refer to Figure 19
Figure 18 - Series I Receiver System Information
Warning:
DO NOT enter anything in the CTCSS fields. If there is already something in any
of those fields, erase their content(s). The indication should be 00.0
5. Select File, Save As. Enter an appropriate name in the “Filename” field. Always use the
suffix .bin for these binary files. Choose the relevant drive and directory to save under
and click on OK.
6. Repeat file creation procedure for the Exciter, the main receiver and for the diversity re-
ceiver modules as required.