5. Testing and Trouble-
Shooting
The checks described below should be done at
time of installation, annual intervals or whenever
deterioration in performance is noted.
5.1 Equipment Required
In-line watt meter (150W & 10 W ranges)
Radio service monitor (IFR-120B with op-
tion 03: 30KHz IF filter or equivalent).
RG-214 or RG-223 cable with N-Type male
connector to connect Paragon
PD
to the serv-
ice monitor.
Important note: Before proceeding make sure
that the service monitor has been calibrated
recently and has warmed up for at least the
time specified by its manufacturer.
Some reported frequency and deviation problems
have actually been erroneous indications from
service monitors that have not adequately
warmed up. This is particularly likely when field
service is done during winter months
.
5.2 Recommended Checks
A)
After an installation
1.
LED Indications
2.
Saveunit config to a file
3.
Transmitter Output Power
4.
Transmitter Reflected Power
5.
RF Link test between Paragon
PD
and mobile
unit(s)
B)
For annual maintenance & trouble-shooting
Same checks as A) plus:
6.
Carrier Frequency Error
7.
TX Deviation
8.
Low Frequency Balance
9.
12 dB SINAD
10.
Receiver distortion
11.