User's Manual

001-2019-500 Rev 0 Paragon4 – UHF, 700 & 800MHz User Manual
7
Table 2 - Test Points
Backplane Test Points Rx/Tx
Test J9 Access port Alternate Pinout
Ground GND Pin 14 J18, J19 – Pin 3
SINAD & Distortion RX1 -Differential 1P-Pin3; 1N-Pin8 J18- Pins 1,2
SINAD & Distortion RX2-Differential 2P-Pin4; 2N-Pin9 J19 – Pins 1,2
RSSI RSSI 1 -Differential 1P-Pin1; 1N-Pin6 J18 – Pins 4,5
RSSI RSSI 2-Differential 2P-Pin2; 2N-Pin7 J19 – Pins 4,5
TX Audio TXAP-Differential (+ve side only) 1P-Pin 5
Key Transmitter /TXKEY-single ended Pin 15
4.4 Electrical Configurations
Standard 120 VAC electrical power is required. It should be capable of providing at least 10A to
power Paragon3 unit (<6A) and ancillary equipment.
4.4.1 Standard Power Supply Configurations
The standard configuration for supplying the required +13.8 VDC to the Paragon4 base station and the
Crescend Power Amplifier is shown in the two figures below, a simple block diagram
and a virtual rack-
mount installation. The base station and the power amplifier module receive 13.8 VDC power inputs
from the ICT22012-70N power supply module powered at 120 VAC.
Figure 5 – Simple AC-to-DC power supply configurations: Block Diagram
120 VAC
AC/DC Power Supply
ICT22012-70N
(34 Amp DC Continuous)
PA
Crescend
Paragon4
Base Station
Preliminary