2x DE-9 RS-232 ports for setup and user data
1x rocker switch (positions PF 1 and 2) to select various test modes. See paragraph 5.3.2.
2x Ethernet ports – for setup and user data
2x Ethernet LEDs (status & activity)
USB port – reserved.
5.1.4 Power Amplifier
Model using Crescend Technologies power amplifier (Illustrations not drawn to scale). The location and
function of the power amplifier's front panel status indicators are shown in Figure xx and described in the
table below:
Table 3 - Power Amplifier indicators
LED Function
DC ON Lights green when DC power (+13.8 VDC) is applied
LOW OUTPUT Lights red when output power drops to approximately 80-85% of set output power
HIGH VSWR
Lights red when VSWR exceeds approximately 2.5:1. At which point, the amplifier
output is reduced. The higher the load VSWR, the more the output power is reduced.
HIGH TEMP
Lights red when the amplifier exceeds a safe operating temperature
(Operating temperature range = -30 °C to +60 °C)
When the heatsink reaches an unsafe level, the output power of the amplifier is re-
duced by approximately 50%. This keeps the channel on-air while providing some
short-term protection. Address the underlying cooling issue as soon as possible.