User's Manual

001-2019-500 Rev 0 Paragon4 – UHF, 700 & 800MHz User Manual
28
6.6.3.1.1 External Analog/Digital Inputs Monitoring
The user can connect and monitor two external analog and four external digital inputs to the backplane
TB1 connector terminals (
Figure 17 and Figure 18).
Figure 17 - Backplane -TB1 connector
Figure 18 - TB1 connector
An external analog device’s voltage must not exceed 30 Volts. The default units of measure used for
monitoring an external device are volts. It is possible to change the default units by creating a look-up
table for the desired unit of measure. This look-up table is created following the guidelines in section
6.8.10.1 and is uploaded into the Paragon4 unit using FTP transfer. Refer to section 6.8.10
TB1
Analog monitoring 2
Analog monitoring 1
Alarm B2 in
p
ut
Alarm B1 in
p
ut
Alarm A2 in
p
ut
Alarm A1 in
p
ut