Note 1: TB1 connector labeling differs from the actual backplane:
TB1 / Web page name(s) TB1 / Backplane name
Power amplifier power
supply
+13V8_PA
Alarm A1 input AL_A1
Alarm A2 input AL_A2
Alarm B1 input AL_B1
Alarm B2 input AL_B2
Analog monitoring 1 AN1
Analog monitoring 2 AN2
6.7 Setup (Basic)
6.7.1 Setup (Basic) General
Used to set four basic operating fields on the connected unit.
Figure 19 - Setup (Basic) – General Setup
Item Description
Station Name
Station name identifier – Enter string up to forty characters in length (letters and/or
numbers)
System ID
Factory default ID is zero. To prevent collision and to minimize interference from re-
mote systems that may be present on the same frequency, Dataradio recommends
changing the System ID to some other value unique to each network.
Upper limit is 255
CWID Call sign
Historically called “Continuous wave ID” – Way of sending FCC license ID using
Morse code
CWID Interval
Interval between CWID messages in minutes
Zero = never.
Preliminary