User's Manual

001-2019-500 Rev 0 Paragon4 – UHF, 700 & 800MHz User Manual
59
6.8.8 Setup (Advanced) Time Source
To facilitate tracking of events in a network, the Paragon4 base station and the GeminiG3 unit can initial-
ize their real-time clocks using a number of protocols. At reset time, the Paragon4 unit can use the SNTP
protocol (RFC2030) to pick up the current UTC (Universal) time. Setting the “TimeZone” and “Daylight
Savings” options allows displaying the correct local time in the “Unit Identification and Status” page.
Figure 51 - Advanced IP Configuration – Time Source
Item Description
SNTP
Client Disabled (Default), Enabled
Server address IP of the SNTP Server in dot decimal format
Period Period at which the SNTP Server is polled
SNTP UTC Time
SNTP UTC Time
Last update received from the SNTP Server (in seconds) - Read-only field.
Time
Zone
TimeZone Select from drop-down list
Daylight Savings Disabled (Default), Enabled
Note: Due to transitional nature of Daylight Saving in many jurisdictions, we recommend that customers use UTC
for consistent, unambiguous time reporting, setting TimeZone to UTC and Daylight Saving to Disabled.
Preliminary