User's Manual

001-2019-500 Rev 0 Paragon4 – UHF, 700 & 800MHz User Manual
78
Unmodulated
Test tone is an unmodulated carrier that gives a clear carrier and used for checking:
Frequency error
Forward and reverse power
Power check:
Connect an in-line power meter between the radio and the antenna.
Measure the forward (nominal 70W (700 & 800 MHz models) or 100W (UHF model)) and re-
flected power levels by pressing the Execute button. For reflected power, never exceed 5%
of forward power or as specified by System Engineering.
100 Hz square
wave
Starts a test transmission of a carrier modulated by a square wave. Used to check low-
frequency balance at a frequency of 100 Hz
Random Data
Starts a 20-second test transmission with a carrier modulated with random data
Random data test transmissions are used for checking low-frequency balance and maxi-
mum deviation over data.
Low-frequency balance check:
Helps to determine if the radio transmitter is well balanced for data transmission.
Refer to the User manual for values indicated in adjustment tables under “Low Fre-
quency Balance” step.
Maximum deviation check:
Helps to verify if the unit is within FCC regulation emission masks.
Refer to the User manual for values.
Random data test requires the use of an IFR COM-120B service monitor with option 03= 30
kHz IF filter and its DC coupled demodulator output selected.
Preliminary