User's Manual

1-14
Part No. 001-4008-101/102
If a simplex radio network is used (i.e. a single frequency for
all stations), we recommend that the master Integra-TR be set
to “master”, the remotes to “remote” and all units to
“selective” data delivery. This will prevent remote stations
from hearing each other's responses.
For full duplex configuration, set the receiving unit Rx/Tx
Mode to Rx Only (using the Field Programming Software).
Set the transmitting unit mode to Tx Only
Figure 1-6 Point-Multipoint System (Full-duplex)
Figure 1-7 Point-Multipoint System (Full-duplex Repeater)
remote
remote
remote
Master
(
half-du
p
lex
)
Full-duplex
repeater
Duplexer
remote
remote
remote
RX TX
Y Cabl
e
730 03350-00x
Duplexer
Master
(full-duplex)
Fan