User's Guide

- 17 - CalAmp Proprietary & Confidential
4.2 Quick Start General Config
All LMU0200Gs™ must go through a common step during the configuration and
provisioning process. Specifically, this is pointing the LMU to the LM Direct™ server, either
via IP or a URL
This configuration process is accomplished via a series of AT Commands.
1. Power up the LMU0200G
2. Power up your handset
3. From the handset, send an SMS message to the LMU0200G‘s phone number:
!RP,768,0,ddd.ddd.ddd.ddd
where ddd.ddd.ddd.ddd is the publicly addressable IPV4 address of the server
4. Alternatively if a URL has been set up for your LM Direct server, the LMU may be
programmed with:
!RP,2319,0,myURL.MyCompany.Com”
Where ―myURL.MyCompany.com‖ is the URL assigned to the server
5. Verify your settings by sending the commands:
!RP?,768,0
!RP?,2319,0