User's Manual

Application Note
Version:
1.0
Feature: Bluetooth Support
Page #:
6 of 11
3.4 LMU user serial message configuration parameters setup example.
If user data packets from the remote device are required to be transmitted to the
backend server at a rate above one per five seconds, the User Message Disposition
S-Register must be set to unacknowledged Message:
S-137< VALUE = 5>
ats137=5
Configure serial message filters:
at$app param 2178,0,""
at$app param 2178,1,""
at$app param 2178,2,""
at$app param 2178,3,""
at$app param 2178,4,""
at$app param 2178,5,""
at$app param 2178,6,""
at$app param 2178,7,""
Use the same as above for 2176 app param:
at$app param 2176,0,""
at$app param 2176,1,""
at$app param 2176,2,""
at$app param 2176,3,""
at$app param 2176,4,""
at$app param 2176,5,""
at$app param 2176,6,""
at$app param 2176,7,""
Ensure that these new configurations do not cause any stream conflicts. Send the
query:
at$app stream?
Below is an example of a stream conflict:
at$app stream?
Stream Port Rate Word
------ ---- ---- ----
0:User0 8:BTPort 9600 8/N/1
1:Modem 4:Radio 115200 8/N/1
2:User1 --
3:Debug 0:Aux1 115200 8/N/1 PREEMPT
4:NMEA Out --
5:DUN --