User's Manual

To ensure proper operation in such an environment, the 4530™ was subjected to standard tests
defined by the Society of Automotive Engineers (SAE). The specific tests included temperature, shock,
vibration, and EMI/EMC. These tests were performed by independent labs and documented in a
detailed test report. In accordance with Appendix A of SAE J1113 Part 1, the Unit is considered a
“Functional Status Class B, Performance Region II” system that requires Threat Level 3 Testing.
The following shows the environmental conditions the LMU is designed to operate in and the relevant
SAE tests that were performed. No formal altitude tests were conducted.
Dimensions
6.356”(L) x 4.429”(W) x 1.725”(H)
158.902mm (L) x 112.496mm (W) x 43.815mm (H)
Weight
2.4oz (68.03g)
Operating Temperature
-30° C to +75° C
-10° C to +60° C (When using Internal Battery Power)
Storage Temperature
-40° C to +85° C
C to +30° C (Long Term w/Internal Battery)
Internal Battery Charging Temperature
+5° C to +45° C
Humidity
0% to 95% relative humidity, at 50° C non-condensing
Shock and Vibration
Ground vehicle environment with associated shock and vibration
SAE Test: SAE J1455
Mil Standard 202G and 810F
Electromagnetic Compatibility (EMC)
EMC compliant for a ground vehicle environment
SAE Test: SAE J1113 Parts 2, 12, 21 and 41
Operating Voltage Range