Crestron Green Light™ DIN-HUB DIN Rail Cresnet® Distribution Hub Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2008 Crestron Electronics, Inc.
Crestron DIN-HUB DIN Rail Cresnet® Distribution Hub Contents Crestron Green Light™ DIN Rail Cresnet® Distribution Hub: DIN-HUB 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Applications......................................................................................................
Crestron DIN-HUB DIN Rail Cresnet® Distribution Hub Crestron Green Light™ DIN Rail Cresnet® Distribution Hub: DIN-HUB Introduction The DIN-HUB is a DIN rail-mounted Cresnet® hub designed to facilitate the configuration of large Cresnet networks. DIN rail mounting enables modular installation alongside Crestron® DIN Rail lighting and automation control modules and other third party DIN rail mountable devices.
DIN Rail Cresnet® Distribution Hub Crestron DIN-HUB Three-Segment Cresnet Hub Cresnet is the communications backbone for Crestron lighting modules, wall box dimmers, shade controllers, thermostats, keypads, touchpanels, and many other devices. This flexible 4-wire bus normally supports approximately 20 Cresnet devices without requiring a hub. Larger systems are easily enabled by adding the DIN-HUB.
Crestron DIN-HUB DIN Rail Cresnet® Distribution Hub Applications The following diagram shows a DIN-HUB in a typical application. DIN-HUB in a Typical Application Operations & Installation Guide – DOC.
DIN Rail Cresnet® Distribution Hub Crestron DIN-HUB Specifications Specifications for the DIN-HUB are listed in the following table. DIN-HUB Specifications SPECIFICATION Power Requirements Cresnet Power Usage Maximum Load per Segment Environmental Temperature Humidity Heat Dissipation Enclosure Dimensions Height Width Depth Weight Available Accessories DIN-BLOCK DIN-PWS50 4 • DIN Rail Cresnet Hub: DIN-HUB DETAILS 0.6 Watts (0.03 Amp @ 24 Volts DC) 75 Watts (3.
DIN Rail Cresnet® Distribution Hub Crestron DIN-HUB Physical Description This section provides information on the connections, controls and indicators available on your DIN-HUB. DIN-HUB Physical View DIN-HUB Overall Dimensions 58 mm (2.28 in) 106 mm (4.17 in) 1 94.2 mm (3.71 in) 90 mm (3.54 in) 2 3 Operations & Installation Guide – DOC.
DIN Rail Cresnet® Distribution Hub Crestron DIN-HUB Connectors, Controls & Indicators # CONNECTORS1, CONTROLS & INDICATORS DESCRIPTION 1 NET PWR INPUT (A/B/C) 2 NET HOST and LEDs (3) 3-pin 3.5 mm detachable terminal blocks Cresnet power selection connectors for each segment Connect to external Cresnet power supplies, or to “host” power source via jumpers, to power devices connected to the NET A/B/C ports Max Wire Size: 1.5 mm2 (16 AWG) Maximum Load per Segment: 75 Watts (3.
Crestron DIN-HUB DIN Rail Cresnet® Distribution Hub Connectors, Controls & Indicators (Continued) # CONNECTORS1, CONTROLS & INDICATORS 2 NET HOST and LEDs (Continued) 3 NET A/B/C and LEDs2 DESCRIPTION (1) Yellow LED indicates Cresnet bus activity at either NET HOST port (6) 4-pin 3.5 mm detachable terminal blocks comprising (2) Cresnet ports (paralleled) per each of (3) segments Max Wire Size: 1.
DIN Rail Cresnet® Distribution Hub Crestron DIN-HUB Industry Compliance This unit has been manufactured to comply with UL’s Standards for Safety in Canada and the United States. Formal approval is pending. As of the date of manufacture, the DIN-HUB has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. NOTE: This device complies with part 15 of the FCC rules.
Crestron DIN-HUB DIN Rail Cresnet® Distribution Hub Setup Network Wiring When wiring the Cresnet® network, consider the following: • Use Crestron Certified Wire. NOTE: Cresnet-HP wire cannot be used. • Use Crestron power supplies for Crestron equipment. • Provide sufficient power to the system. CAUTION: Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (www.crestron.
DIN Rail Cresnet® Distribution Hub Crestron DIN-HUB The DIN-HUB is designed for installation on a DIN rail. Refer to the following diagram when installing. Installing the DIN-HUB DIN-HUB TOP DIN RAIL (NOT SUPPLIED) DIN RAIL RELEASE 1. Place the top of the DIN-HUB’s rail mount over the top of the DIN rail. 2. Tilt the bottom of the DIN-HUB toward the DIN rail until it snaps into place.
Crestron DIN-HUB DIN Rail Cresnet® Distribution Hub Hardware Hookup Make the necessary connections as called out in the illustration that follows this paragraph. Refer to “Network Wiring” on page 9 before attaching the 4-position terminal block connector. Apply power after all connections have been made. When making connections to the DIN-HUB, use a Crestron power supply. Hardware Connections for the DIN-HUB NET PWR INPUT: 24 VDC JUMPERED FROM NET HOST PORT or EXTERNAL SUPPLY.
DIN Rail Cresnet® Distribution Hub Crestron DIN-HUB Power can be supplied from a DIN-PWS50 DIN Rail Power Supply or other Cresnet power supply connected to the NET HOST port. For more information, refer to the latest version of the DIN-PWS50 Operations & Installation Guide (Doc. 6667), which is available for download from the Crestron website (www.crestron.com/manuals). NOTE: The DIN-HUB can only be powered by the NET HOST port.
DIN Rail Cresnet® Distribution Hub Crestron DIN-HUB Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. DIN-HUB Troubleshooting TROUBLE POSSIBLE CAUSE(S) NET HOST PWR LED does not illuminate. DIN-HUB is not receiving power. Segment’s NET LED does not illuminate. Segment is improperly wired.
DIN Rail Cresnet® Distribution Hub Crestron DIN-HUB DIN-HUB Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) Segment’s PWR Incorrect wiring at LED does not NET PWR INPUT port. illuminate. Insufficient power. Network not Wiring problem. working and only one LED is illuminated. CORRECTIVE ACTION Verify that the NET PWR INPUT port is wired correctly for internal or external power. Verify that sufficient power is available. If necessary, connect the NET PWR INPUT port to an external power supply.
DIN Rail Cresnet® Distribution Hub Crestron DIN-HUB Cresnet units are to be daisy-chained on the run, the Cresnet power usage of each network unit to be daisy-chained must be added together to determine the Cresnet power usage of the entire chain. If the unit is home-run from a Crestron system power supply network port, the Cresnet power usage of that unit is the Cresnet power usage of the entire run.
DIN Rail Cresnet® Distribution Hub Crestron DIN-HUB List of Related Reference Documents DOCUMENT TITLE DIN-PWS50 DIN Rail 50 Watt Cresnet Power Supply Further Inquiries If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling Crestron at 1-888-CRESTRON [1-888-273-7876]. You can also log onto the online help section of the Crestron website (www.crestron.
Crestron DIN-HUB DIN Rail Cresnet® Distribution Hub Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.
DIN Rail Cresnet® Distribution Hub Crestron DIN-HUB This page is intentionally left blank. 18 • DIN Rail Cresnet Hub: DIN-HUB Operations & Installation Guide – DOC.
DIN Rail Cresnet® Distribution Hub Crestron DIN-HUB This page is intentionally left blank. Operations & Installation Guide – DOC.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations & Installation Guide – DOC. 6671A (2020753) 05.08 Specifications subject to change without notice.