User Guide

Technical specifications
Materials:
Body: DZR low-lead brass EN 12165 CW724R
Adjustable cartridge: PSU
Springs: stainless steel AISI 302 (EN 10270-3)
Hydraulic seals: peroxide-cured EPDM
Adjustment knob: ABS
Performance:
Suitable fluid: water
Max. working pressure: 230 psi (16 bar)
Max. differential pressure: 15 psi (1 bar)
Max. inlet temperature: 195°F (90°C)
Adjustment temperature range: 105–150°F (40 – 65°C)
Factory setting: 135°F (58°C)
Flow Cv (Kv) max: 2.1 (1.8)
Flow Cv (Kv) min: 0.35 (0.3)
Flow Cv (Kv) design: 0.69 (0.6)
Connections:
Main connections:
½" and ¾" NPT female
Temperature gauge/sensor dry-well: Ø 10 mm metric
Temperature gauge code 116010
Scale: 30 - 180°F (0–80°C)
Diameter: 1½" (40 mm)
Stem diameter: 0.35" (9 mm)
Technical specifications of insulation
Materials: closed cell expanded PE-X
Thickness: ½ inch (13 mm)
Density: -internal part: 1.9 lb/ft³ (30 kg/m³)
-external part: 5.0 lb/ ft³ (80 kg/m³)
Thermal conductivity (DIN52612):
- at 32°F (0°C): 0.82 BTU · in/hr · ft² · °F (0.0345 W/(m · K))
- at 105°F (40°C): 0.94 BTU · in/hr · ft² · °F (0.0398 W/(m · K))
Coefficient of resistance to the diffusion of vapor: > 1,300
Working temperature range: 32–212°F (0–100°C)
Flammability (ASTM D 635): Class VO
Certications:
1. Complies with codes IPC, IRC, UPC and NPC and standard
NSF/ANSICAN 61, as certified by ICC-ES, file PMG-1512 (180°F/82°C
Commercial Hot).
2. Complies with NSF/ANSI 372, low lead, as certified by ICC-ES, file
PMG-1360.
01365/20.1 NA
ThermoSetter
Recirculation thermal balancing valve
1164 series
Function
The ThermoSetter 1164 series adjustable thermal balancing valve is used for
automatic balancing of recirculation loops in domestic hot water systems, to
speed hot water delivery, reduce water waste and save energy. The internal
thermostatic balancing cartridge automatically modulates flow to ensure a
constant temperature in the recirculation piping system. The 116 Series has
an adjustment knob with 105°F to 150°F (40°C to 65°C) temperature scale
indication. The adjustment knob is lockable for tamper-proofing. An integral
dry-well holds a slide-in temperature gauge for local indication, or a sensor for
remote temperature sensing. The optional check valve protects against circuit
thermo-syphoning.
The valve complies with NSF/ANSI/CAN 61, as certified by ICC-ES, file PMG-
1512 (180°F/82°C Commercial Hot), and complies wirh NSF/ANSI 372, low lead
laws, as certifed by ICC-ES, file PMG-1360. It also meets codes IPC, IRC, UPC
and NPC for use in accordance with the US and Canadian plumbing codes.
003
FM 21654
Product range
1164 series
Thermal balancing valve, models with and without temperature gauge, with and without check valve .......................................size ½” & ¾” NPT female
NSF/ANSI/CAN 61