Product Overview

01149/11 NA
Replaces 01149/10
QuickSetter™ Balancing
valve with flow meter
132 series
Product range
132 series Balancing valve with flow meter sizes 1/2”, 3/4”, 1”, 1 1/4”, 1 1/2”, and 2"
CALEFFI
a
a
a
a
a
a
a
a
a
a
a
a
aaa
a
a
a
a
a
a
D
5 3/4
5
3/4
6
1/4
6
1/2
6
3/4
7”
C
1
13/16
1
13/16
1
7/8
2”
2
1/4
2
1/2
B
3
5/16
3
5/16
3
3/8
3
1/2
3
5/8
3
3/4
Weight (lb)
2.0
1.8
2.4
2.8
3.4
4.4
A
1/2”
3/4”
1”
1 1/4”
1 1/2”
2”
Code
132432A
132552A
132622A
132772A
132882A
132992A
A B
C
A
D
C
AL EFFI
b
ar
1
5
7
6
5
4
3
2
Dimensions
Technical specifications
Materials
Valve
Body: brass
Ball: brass
Ball control stem: brass, chrome plated
Ball seal seat: PTFE
Control stem guide: PSU
Seals: EPDM
Flow meter
Body: brass
Bypass valve stem: brass, chrome plated
Springs: stainless steel
Seals: EPDM
Flow meter float and indicator cover: PSU
Performance
Suitable Fluids: water, glycol solutions
Max. percentage of glycol: 50%
Max. working pressure: 150 psi (10 bar)
Working temperature range: 14 - 230°F (-10–110°C)
Flow rate range unit of measurement: gpm
Accuracy: ±10%
Control stem angle of rotation: 90°
Control stem adjustment wrench: 1/2”–1 1/4”: 9 mm
1 1/2” and 2": 12 mm
Threaded connections: 1/2”– 2" FNPT
Flow rate correction factor: 20%-30% glycol solutions: 0.9
40%-50% glycol solutions: 0.8
Insulation
Material: closed cell expanded PE-X
Thickness: 25/64 inch (10 mm)
Density: - inner part: 1.9 lb/ft
3
(30 kg/m
3
)
- outer part: 3.1 lb/ft
3
(50 kg/m
3
)
Thermal conductivity (DIN 52612):
- at 32°F (0°C): 0.263 BTU·in/hr·ft
2
·°F (0.038 W/(m·K))
- at 104°F (40°C): 0.312 BTU·in/hr·ft
2
·°F (0.045 W/(m·K))
Coefficient of resistance to water vapor (DIN 52615): > 1,300
Working temperature range: 32 - 212°F (0–100°C)
Reaction to fire (DIN 4102): class B2
Flow rate ranges
ACCREDITED
ISO 9001 No. 0003
ISO 9001 FM 21654
Function
The 132 series balancing valve accurately sets the flow rate of
heating and cooling transfer fluid supplied to fan coils and terminal
units or where flow balancing is required in solar thermal systems.
Proper hydronic system balancing ensures that the system
operates according to design specifications, providing satisfactory
thermal comfort with low energy consumption. The flow meter is
housed in a bypass circuit on the valve body and can be shut off
during normal operation. The flow meter permits fast and easy
circuit balancing without added differential pressure gauges and
reference charts. The balancing valve is furnished with a pre-
formed insulation shell to optimize thermal performance for both hot
and cold water systems.
Patent application No. MI2007A000703.
Code Connection
Flow rate (GPM)
Cv
132432A 1/2” NPT 1/2 – 1 3/4 1.0
132552A 3/4” NPT 2.0 – 7.0 6.3
132662A 1” NPT 3.0 – 10.0 8.3
132772A 1 1/4” NPT 5.0 – 19.0 15.2
132882A 1 1/2” NPT 8.0 – 32.0 32.3
132992A 2” NPT 12.0 – 50.0 53.7