Function
The QuickSetter+™ static balancing valve contains a built-in flow
meter and sight gauge, negating the need for differential pressure
gauges and reference charts. Circuit balancing is fast, easy and
accurate. Constructed of DZR low-lead brass, QuickSetter+™ is
ideally suited for use in plumbing applications such as hot water
recirculation systems. The built-in check valve protects against
circuit thermo-siphoning. The outlet temperature gauge (optional)
verifies the fluid temperature in the circuit. The flow meter sight
gauge is dry (not exposed to the fluid) thus eliminating the possibility
of gauge clouding/scaling over time. The QuickSetter+™ can also
be used in heating systems.
Product range
132 Series Balancing valve with flow meter sizes 1/2”, 3/4”,
and 1”. Includes check valve and optional outlet
temperature gauge.
Technical characteristics
Valve
Materials: Body and ball: DZR low-lead brass
Ball: stainless steel
Ball control stem: brass, chrome plated
Ball seal seat: PTFE
Control stem guide: PSU
Seals: EPDM
Flow meter
Materials: Body and headwork: DZR low-lead brass
Bypass valve stem: stainless steel
Springs: stainless steel
Seals: EPDM
Flow meter float and indicator cover: PSU
Performance: Max. working pressure: 150 psi (10 bar)
Max. glycol percentage: 50%
Working temperature range: 14 - 230°F (-10–110°C)
Flow rate range unit of measurement: ½ – 1¾ gpm
2 – 7 gpm
Accuracy: ±10%
Control stem angle of rotation: 90°
Required operating wrench: 9 mm
Connections: ½”, ¾”, 1” union sweat, PEX crimp;
¾” union press
Lay length (press connection):
size
¾” without gauge: 7
5
/16
size ¾” with gauge: 10
1
/8
NSF/ANSI 372-2011, Drinking Water System Components-Lead Content
Reduction of Lead in Drinking Water Act, California Health and Safety Code
116875 S.3874, Reduction in Drinking Water Act, certified by ICC-ES, file PMG-1360.
QuickSetter+™ Balancing Valve with flow meter
132 Series
© Copyright 2018 Caleffi
NA18070.03
www.caleffi.com