Submittal Sheet

CALE FFI
DIRTCAL
®
Dirt Separator
5462 Series
Submittal Data 02925 NA — Issue Date 04/2011
Dimensions
CDE
A
B
NPT
We reserve the right to change our products and their relevant technical data, contained in this publication, at any time and without prior notice. Contractors should request production drawings if prefabricating the system.
Job name ______________________________________
Job location ______________________________________
Engineer ______________________________________
Mechanical contractor ________________________________
Contractor’s P.O. No. ________________________________
Representative ________________________________
Size ________________________________________
Quantity ________________________________________
Approval ________________________________________
Service ________________________________________
Tag No. ________________________________________
Notes ________________________________________
Caleffi North America, Inc. 3883 West Milwaukee Road / Milwaukee, WI 53208
Tel: 414.238.2360 / Fax: 414.238.2366 / www.caleffi .us
© Copyright 2011 Caleffi
(kPa)
1
0.1
0.2
0.5
0.9
0.8
0.7
0.6
0.12
0.14
0.16
0.18
0.25
0.3
0.35
0.4
0.45
1.2
1.4
1.6
1.8
2.5
3
2
0.09
0.08
0.07
0.06
0.1
0.05
0.09
0.08
0.07
0.06
0.035
0.04
0.045
0.12
0.14
0.16
0.18
0.25
0.3
0.35
0.2
1
0.5
0.9
0.8
0.7
0.6
0.45
0.4
0.025
0.03
0.
0
2
(ft of water)
1"
1 1/4"
1 1/2"
3/4"
2”
ΔP (ft of water)
0.1
0.05
0.09
0.08
0.07
0.06
0.035
0.04
0.045
0.12
0.14
0.16
0.18
0.25
0.3
0.35
0.2
1
0.5
0.9
0.8
0.7
0.6
0.45
0
.4
0.025
0.03
0.
0
2
G (l/s)
1.25
1.7
1.9
2.2
2.5
3.3
3.9
4.4
5.0
0.44
0.50
0.69
0.97
0.83
1.1
0.39
0.33
5.6
2.8
1.4
0.56
0.13
0.25
0.22
0.19
0.16
0.27
100
2
10
5
20
50
6
7
8
9
12
14
16
18
25
3
0
35
40
45
60
70
80
90
3
3
.5
4
4.5
2.5
(gpm)
ACode B C D E Weight (lb) (kg)
546205A 3/4" NPT 4 5/16" 1 1/4" 5" 2" 4.2 1.9
546206A 1" NPT 4 5/16" 1 1/4" 5" 2" 4.2 1.9
546207A 1 1/4" NPT 4 7/8" 1 1/4" 6" 2" 5.3 2.4
546208A 1 1/2" NPT 4 7/8" 1 1/4" 6" 2" 5.3 2.4
546209A 2" NPT 5 1/8" 1 1/4" 6" 2" 5.3 2.4
546228A 1" Sweat 5 1/16" 1 1/4" 5" 2" 4.2 1.9
546235A 1 1/4" Sweat 5 3/16" 1 1/4" 6" 2" 4.2 1.9
546241A 1 1/2" Sweat 5 3/4" 1 1/4" 6" 2" 4.9 2.2
546254A 2" Sweat 6 1/8" 1 1/4" 6" 2" 5.5 2.5
A
Size
GPM
L/sec.
Cv
1 1/4”
1 1/2”
1”3/4”
2”
6.0
0.4
18.8
9.3
0.6
32.6
15.3
1.0
56.6
23.9
1.5
73.3
36.0
2.3
81.0
Flow Capacity
Hydraulic Characteristics
Application
In heating and air conditioning control systems, the circulation of water
containing impurities may result in rapid wear and damage to components such
as pumps and control valves. It also causes blockages in heat exchangers,
heating elements and pipes, resulting in lower thermal ef ciency within the
system. The dirt separator separates off these impurities, which are mainly made
up of particles of sand and rust, collecting them in a large collection chamber,
from which they can be removed even while the system is in operation. This
device is capable of effi ciently removing even the smallest particles, with very
low head loss. Patented.
Typical Speci cation
Furnish and install on the plans and described herein, a Caleffi DIRTCAL® Dirt
Separator as manufactured by Calef . Each separator must be designed with a
blowdown drain port. The separator design must include a large internal volume
and a removable PA66G30 glass-fi ber reinforced nylon internal mesh element
screen to automatically remove all dirt present in the system, with particle
separating capacity to 5μm (0.2 mil). Each dirt separator shall be a Caleffi model
5462 or approved equal.
(See product instructions for specifi c installation information.)
Technical Speci cations
Materials:
- Body, dirt collection chamber and top plug: brass
- Int. element: PA66G30
- Hydraulic seal: EPDM
- Drain valve: brass
Suitable fl uids: water, glycol solution
Max percentage of glycol: 50%
Max working pressure: 150 psi (10 bar)
Temperature range: 32–250°F (0–120°C)
Particle separation capacity: to 5 μm (0.2 mil)
Connections:
- Main: 3/4”, 1”, 1 1/4”, 1 1/2”, 2” NPT female
1”, 1 1/4”, 1 1/2“, 2” sweat
- Top: 1/2” F (with plug)
- Drain: 3/4” garden hose
Flow Capacity
The maximum fl uid velocity recommended at the unit connections is ~ 4
f/s. The following table shows the maximum fl ow rates to comply with this
condition.
DCE
A
B
Sweat

Summary of content (1 pages)