Product Manual

10 Customer Support: 1-866-409-4581
AIR COMPRESSOR
MAINTeNANCe
draining the a ir t ank
The frequency at which you should drain the air tank and air dryer
depends on the environmental conditions and the amount of
operating time logged. d aily draining is recommended to not
damage the air compressor motor, dryer, tank and components.
1. Place the air compressor above a container capable of holding
water. A pan with a dry towel would be advised.
Locate the drain valve at the bottom of the air tank.
2. Without compressed air in the air tank, slowly turn the drain valve
knob to the forward (open) or straight down position.
The water in the air tank will drain out.
3. After all of the accumulated water has drained out, turn the drain
valve knob to the closed or left position in order to avoid leakage.
draining the a ir dryer
1. At the bottom of the air drying column is a drain hole with a drain
tube attached.
Attach the other end of the drain tube to a container capable of
holding water. This tube will let the water from the air dryer drain.
2. Remove waste container and empty.
c hanging the a ir f ilter
The air filters are designed to reduce noise and help prevent
particulates in the air from entering and damaging the air
compressor.
After being used for a period of time, the air filter will become
clogged. This will reduce the air intake capabilities of the air
compressor, reducing performance. Therefore, the air filter must be
replaced regularly.
1. Open the lid of the air filter and remove the old air filter element.
2. Replace with a new air filter element and close the lid.
t esting for l eaks
Make sure all connections are tight. d o not overtighten.
A small leak in any hose or pipe connection will reduce the air
compressor's performance.
To test for small leaks, spray a small amount of soapy water on the
area suspected of leaking. If the soap bubbles, replace the broken
part.
c leaning
Clean items with a soft brush, or wipe with a moistened cloth using
a biodegradable solvent.
d o not use flammable liquids such as gasoline or alcohol. Always
keep parts clean from dirt and dust for better performance.
a ir drying c olumn - d esiccant
After 4000 hours of use the Activated Alumina d esiccant needs to
be replaced.
u nscrew the air drying column bottom cap.
Remove the old desiccant (disguard) and add new desiccant.
STORAg e
before storing for a prolonged period of time:
1. Turn off the power supply.
2. d isconnect the power cord from the power supply.
3. Pull the relief valve and release all the pressure from the air tank.
4. Clean the air compressor to remove all dirt and dust.
5. Cover the air compressor with a cover to protect the unit from
dust and moisture.
6. d o not stack or store any items on top of or around the air
compressor. d amage could occur.