Installation Sheet

CF-KXX-110_ii_150901 Pg 4
5
MAINTENANCE
SPRAYHEAD
Caution: Place drain strainer or towel in sink drain to prevent parts
from falling down the drain.
Use KEY (14) to remove SHELL (8a), SPRAY-
FACE (8b), aerator INSERT (8c) and WASHER
(8d)
Rinse all parts with clean water to remove any
debris
Replace all parts is opposite order as described
above
CARTRIDGE
Caution: Turn off HOT and COLD supply stops before
proceeding.
Remove SETSCREW (10a) from HANDLE (10)
Slide HANDLE (10) off
Remove BONNET (11), PACKING NUT (12) and
slide CARTRIDGE (13) out
Rinse CARTRIDGE (13) with clean water to
remove any debris
Replace all parts is opposite order as described
above
Important: The PACKING NUT (12) must be securely tightened to
prevent leaking. The tightening torque shall be 70-90 lbs.-in. If
CARTRIDGE (13) is overtightened, CARTRIDGE (13) may not
function properly including possible damage to CARTRIDGE (13).
californiafaucets.com 5271 Argosy Ave. Huntington Beach, CA 92649 800-822-8855