34 HYDRA2 Operator Manual
Using H20
METADATA AND EMBER CONTROL
SMPTE2020 metadata can be 
inserted into chosen Hydra2 SDI 
output streams using a 3rd party 
EMBER controller.
The EMBER controller can choose from 
a list of metadata sets stored by H2O. 
To make a metadata set available for 
selection by the EMBER controller, the 
metadata set needs to be imported into 
H2O in the form of an XML file.
The Manage metadata page in H2O 
displays a list of the metadata sets 
available for selection. The Files “+” and 
“-” buttons at the bottom of the screen 
allow for files to be added and removed 
from the list.
As well as inserting metadata into 
SDI outputs, EMBER controllers can 
selectively mute any of the audio channel 
pairs within each SDI output. 
EMBER controllers also have the ability to 
change the active user memory on control 
surfaces as well as changing audio I/O 
patching on control surfaces by activating 
and deactivating I/O port alias files. For 
more information on user memories and 
port aliasing, please refer to a console 
operator manuals.
Please refer to the Hydra 2 installation 
manual for more information on EMBER 
controllers and connecting them to a 
Hydra2 network.