Product Description

Table Of Contents
Test report
Our reference : 21BE0029YW-1
Page : 11of 12
Issued date : October 5, 2000
FCC ID : KBRASTU13
Testing Laboratory
A-pex International Co., Ltd.
Telephone: +81 596 39 1485
108 Yokowa-cho, Ise-shi Mie-ken 516-1106 JAPAN Facsimile: +81 596 39 0232
6 TEST EQUIPMENT USED
INSTRUMENTS Mfr. MODEL C/N Calibrated Until
Pre Amplifier Hewlett Packard 8447D AF1 November 16, 2000
Pre Amplifier Anritsu MH648A AF3 November 16, 2000
Pre Amplifier Hewlett Packard 8449B AF4 November 16, 2000
Attenuator Anritsu MP721B AT6 June 8, 2001
Biconical Antenna Schwarzbeck BBA9106 BA1 April 28, 2001
Biconical Antenna Schwarzbeck BBA9106 BA3 April 28, 2001
Biconical Antenna Schwarzbeck BBA9106 BA5 April 28, 2001
Horn Antenna A.H. Systems SAS200/571 HA1 February 4, 2001
Logperiodic Antenna Schwarzbeck UHAP9108-A LA6 April 29, 2001
Logperiodic Antenna Schwarzbeck UKLP9140-A LA8 April 29,
2001
Loop Antenna Rohde & Schwarz HFH2-Z2 LP1 November 3, 2000
LISN Rohde & Schwarz ESH2-Z5 LS1 November 15, 2000
LISN Rohde & Schwarz ESH3-Z5 LS2 November 15, 2000
LISN Schwarzbeck NSLK8127 LS3 November 15, 2000
LISN Rohde & Schwarz ESH3-Z5 LS4 November 15, 2000
LISN Schwarzbeck NNLK8121 LS5 November 15, 2000
LISN Rolf Heine NNB-4/200 LS6 November 15, 2000
LISN Schwarzbeck NNLK8126 LS7 November 15, 2000
LISN Schwarzbeck NSLK8127 LS10 April 8, 2001
Spectrum Analyzer Hewlett Packard 8567A SA3 December 13, 2000
Spectrum Analyzer Hewlett Packard 8567A SA4 December 13, 2000
Spectrum Analyzer Advantest R3271 SA5 September 27, 2000
Test Receiver Rohde & Schwarz ESHS-20 TR1 March 30, 2001
Test Receiver Rohde & Schwarz ESVS-30 TR2 July 13, 2001
Test Receiver Rohde & Schwarz ESCS30 KTR1 August 7, 2001
indicates EMI Test Equipment used.
*All measurement equipment is traceable to national standard.