Test report
Our reference : 21BE0029YW-1
Page : 9of 12
Issued date : October 5, 2000
FCC ID : KBRASTU13
Testing Laboratory
A-pex International Co., Ltd.
Telephone: +81 596 39 1485
108 Yokowa-cho, Ise-shi Mie-ken 516-1106 JAPAN Facsimile: +81 596 39 0232
4 RADIATED EMISSION DATA
The initial step in collecting radiated data was a spectrum analyzer peak scan of the measurement range (30MHz-3300MHz).
The final data was reported in the worst-case emissions.
The minimum margin to the limit is as follows :
Receiver Correction Field
Frequency Reading Factor Strength Limit Margin
(MHz) (dB
μ
V) (dB
μ
V) (dB
μ
V/m) (dB
μ
V/m) (dB
μ
V)
315.00 78.2 -3.8 74.4 75.6 1.2
* quasi-peak mode
The Fundamental Frequency of this equipment is 315MHz. The peak of output level of fundamental frequency was
confirmed at the 315MHz by perfarming the meaurement.
It was corroborated that equipment was within of the tolerance which is prescribed
in the FCC requlation Part 15 Subpart C sec. 15.231 (c).
Since the fundamental frequency is 315MHz, the upper limit could be 315.8 MHz and lower limit could be 314.2MHz.
The measurement result was 315.2MHz when the limit was 315.8MHz and also another measurement result was 314.8 MHz
when the limit was 314.2MHz.