User's Manual

Chapter 7: Configuration
General configuration
Page 7-81
Attribute
Meaning
Timing Mode
Allows the user to choose the mode between Timing Master and
Timing Slave.
Link Speed
See Table 113 General page attributes PMP 450i AP on page 7-70
802.3at Type 2 PoE
Status and
PoE Classification
When the PoE Classification functionality is enabled and if Type 2
power is not present, the PAs do not power up and draw too much
power.
By default, the PoE Classification feature is disabled and the PAs will
power up regardless of the classification presented by the power
source.
This is supported only on 450i Series ODUs.
PoE Classification configuration status also can be check under home
> General > Device Information tab:
Sync Input
See Configuring synchronization on page 7-95
Region
See Table 113 General page attributes PMP 450i AP on page 7-70
Country
Webpage Auto Update
Bridge Entry Timeout
Bridging Functionality
Select whether you want bridge table filtering active (Enable) or not
(Disable) on this BH.
Disable: allows user to use redundant BHs without causing network
addressing problems. Through a spanning tree protocol, this reduces
the convergence time from 25 minutes to few seconds. However, you
must disable bridge table filtering as only a deliberate part of your
overall network design since disabling it allows unwanted traffic
across the wireless interface.
Enable: Allows user to enable bridge functionality.
Note
Specify the appropriate bridge timeout for correct
network operation with the existing network
infrastructure. The Bridge Entry Timeout must be a
longer period than the ARP (Address Resolution
Protocol) cache timeout of the router that feeds the
network.
Prioritize TCP ACK
See Table 113 General page attributes PMP 450i AP on page 7-70
Multicast Destination
Address