Hazardous locations
Check that the ODUs will not be exposed to hazardous gases, as defined by HAZLOC (USA) and
ATEX (Europe) regulations. If there is a risk of such exposure, then order the PTP/PMP 450i
ATEX/Hazloc product variants, as these are intended for operation in locations with gas hazards.
The ATEX and HAZLOC standards limit the EIRP as shown in Table 66.
Table 66 EIRP limits from ATEX and HAZLOC standards
ATEX gas
group
HAZLOC gas
group
Typical gas type
Maximum EIRP
(Watt)
IIA
D
Propane
6
IIB
C
Ethylene
3.5
IIC
B
Hydrogen
2
IIC
A
Acetylene
2