Chapter 7: Configuration
Configuring synchronization
Page 7-95
Configuring synchronization
Applicable products
PMP :
AP
PTP:
BHM
This section describe synchronization options for PMP and PTP configuration.
This Sync Input parameter can be configured under Sync Setting tab of Configure > General page
(see General configuration on page 7-70).
PMP/PTP 450i Series has following synchronization options:
AutoSync
AutoSync + Free Run
Generate Sync
Free Run Before GPS Sync
Figure 123 Sync Setting configuration
AutoSync
For PTP, the BHM automatically receives sync from one of the following sources:
GPS Sync over Timing Port (UGPS, co-located AP GPS sync output, or “Remote ” Device feed
from a registered SM’s GPS sync output)
GPS Sync over Power Port (CMM4)
Upon AP/BM power on, the AP/BHM does not transmit until a valid synchronization pulse is
received from one of the sources above. If there is a loss of GPS synchronization pulse, within two
seconds the AP/BHM automatically attempts to source GPS signaling from another source.
In case of PMP, when there are synchronization sources on both the timing port and the power
port, the power port GPS source is chosen first.
If no valid GPS signal is received, the AP/BHM ceases transmission and SM/BHS registration is lost
until a valid GPS signal is received again on the AP or BHM.
Note
After an AP reboot, the sync acquisition takes a little longer than it had on 450i