User's Manual

Chapter 10: Reference Information
Equipment Disposal
Page 10-45
Table 253 Default combined transmit power per country 5.4 GHz band PMP 450 Series
Countries
Device
Type
Antenna
Type
Channel BW
Conducted
Power Limit
(dBm)
EIRP
Limit
(dBm)
United States, Canada,
Brazil, Australia, Denmark,
Finland, Germany, Greece,
Liechtenstein, Norway,
Portugal, Spain, UK, Vietnam
AP
Sector (18
dBi 1dB
cable loss)
10 MHz
10
27
20 MHz
13
30
Austria, Belgium, Bosnia &
Herzegovina, Bulgaria,
Croatia, Cyprus, Czech
Republic, France, , Hungary,
Ireland, Italy, Latvia,
Lithuania, Luxembourg,
Macedonia, Malta,
Netherlands, Poland,
Romania, Slovakia,
Slovenia , Sweden
AP
Sector (18
dBi 1dB
cable loss)
10 MHz
10
27
*
20 MHz
13
30
Algeria
AP
Sector (18
dBi 1dB
cable loss)
10 MHz
10
27
20 MHz
13
30
Other
AP
Sector (18
dBi 1dB
cable loss)
10 MHz
19
No EIRP
limit
20 MHz
19
No EIRP
limit
(*) At 5.4 GHz, EU regulations are harmonized. 5600 5650 MHz excluded, as ten minute Channel
Availability Check (CAC) is required