User's Guide Part 1

User Guide: PTP 600 Series Lightning protection
phn-0896_009v003
Feb 2010
UNDER DEVELOPMENT
2-19
Lightning protection zones
Lightning protection zones are determined by using the ‘rolling sphere method’
(Figure 2-6). As
sess locations on masts, towers and buildings to determine if the
location is in Zone A or Zone B:
Zone A: In this zone a direct lightning strike is possible. Do not mount the ODU
and antenna in this zone.
Zone B: In this zone, direct EMD (lightning) effects are still possible, but
mounting in this zone significantly reduces the possibility of a direct strike.
Mount the ODU and antenna in this zone.
WARNING
Never mount the ODU in Zone A. Mounting in Zone A may put
equipment, structures and life at risk.
Figure 2-6 Rolling sphere method to determine the lightning protection zones
ODU
Zone B
Zone A
Zone A
50 m
Zone B