User's Guide Part 2

User Guide: PTP 600 Series Installing connectorized bridges
phn-0896_009v003
Feb 2010
UNDER DEVELOPMENT
8-17
Aligning separate antennas
When using separate antennas to achieve spatial diversity, one should be mounted
with Horizontal polarization and the other with Vertical polarization. Follow Procedure
8-1
Proce
dure 8-1 Aligning separate antennas
1
Mount the Antennas.
2
Mount the connectorized version of the PTP 600 ODU.
3
Route and make off the ends of the Antenna cables.
4
Connect the antenna cables at the antennas.
5
Connect one of the antenna cables at the Connectorized version of the PTP 600
Series unit.
6
Connect the Connectorized PTP 600 Series ODU to PIDU Plus cable and
configure the unit as described in Connecting the ODU, PIDU and LPUs on
page 5-43.
7
Align the connected antenna using the tones as described in
Using the ODU
installation tones on page 5-59.
8
Connect the other antenna to the ODU.
9
Disconnect the cable to the already aligned antenna.
10
Align the second antenna using the tones as described in
Using the ODU
installation tones on page
5-59.
11
Re-connect the second antenna to the Connectorized PTP 600 Series. The tone
pitch should increase due to the additional received signal.
12
Use the relevant status web pages to check that the planned link performance is
achieved.