User's Guide Part 2

User Guide: PTP 600 Series Additional lightning protection
phn-0896_009v003
Feb 2010
UNDER DEVELOPMENT
8-21
ODU mounted indoors
Where the ODU is mounted indoors, lightning arrestors should be deployed where the
antenna cables enter the building as shown in Figure 8-10.
Fi
gure 8-10 Lightning arrestor mounting
The lighting arrestors should be ground bonded to the building ground at the point of
entry. Motorola recommends Polyphaser LSXL-ME or LSXL lighting arrestors. These should
be assembled as show in Figure 8-11.