User's Guide Part 2

Cable connection procedures Chapter 5 Installation
phn-0896_009v003
5-18
UNDER DEVELOPMENT
Feb 2010
Disconnecting the drop cable from an ODU or LPU
NOTE
This procedure contains illustrations of an ODU, but it applies in principle to
both the ODU and the LPU.
To disconnect the supported Superior Essex cable with a gland from a unit (LPU or
ODU), proceed as follows:
Procedure 5-9 Disconnect the drop cable with a gland from a unit (LPU or ODU)
1
Remove the gland back shell.
2
Wiggle the drop cable to release the tension of the gland body.
When the tension in the glad body is released, a gap opens at the point shown in
red in the above photograph.
3
Unscrew the gland body.
4
Use a small screwdriver to depress the RJ45 locking cap
5
Unplug the RJ45.