Restoring, resetting and rebooting Chapter 7 Operation
phn-2182_002v000
7-26
May 2011
Resetting to default configuration (with country reset)
Use the reset plug (supplied in each PTP 250 ‘Link Complete’ or ‘End Complete’ kit) to
reset the unit to factory default configuration, including reset of the country of
operation (this will have to be reselected at first login after the reset).
CAUTION
When the unit is reset to default configuration, the current configuration is
lost and the unit reboots, causing loss of service.
NOTE
To reset the unit to factory defaults without resetting the country of
operation, follow the procedure in Resetting to default configuration
(wi
thout country reset) on page 7-25.
To
reset to default configuration including country reset, proceed as follows:
1
Remove the ODU drop cable from the PoE power supply DATA & POWER
OUT port.
2
Plug the ODU drop cable into the reset plug and then plug the reset plug
into the PoE power supply DATA & POWER OUT port (Figure 7-13).
3
Wait for at least 45 seconds.
4
Disconnect the reset plug and re-insert the ODU drop cable into the PoE
power supply DATA & POWER OUT port.
5
The unit should now be reset to factory default settings, including the
following:
Password ‘motorola’,
IP address ‘169.254.1.1’,
Master Slave Status ‘Slave’,
Country Code is blank.
6
To reconfigure the unit, follow the instructions in Connecting to the unit
on page 6-3 an
d Using the installation wizard on page 6-14.
NOTE
When logging into the unit, change Password and select Country
Code (these will be prompted).