Restoring, resetting and rebooting Chapter 7 Operation
phn-2182_002v000
7-28
May 2011
Recovering a lost IP address
To recover a lost IP address, physical access to the PoE power supply is recommended.
NOTE
The unit does still respond to its normal IP address through a power cycle.
If the IP address of the unit has been lost or forgotten, proceed as follows:
1
Set the management PC Ethernet port to an IP address that is valid for
the 169.254.X.X network, avoiding 169.254.0.0, 169.254.1.1 and
169.254.1.2. Refer to Configuring the management PC on
page 6-3.
2
Connect the management PC Ethernet port to the DATA IN port of the
PoE power supply using a standard (not crossed) Cat5e cable (Figure
6-3).
3
Perform a power cycle, that is, disconnect and then reconnect the PoE
power supply to its AC supply.
4
Access the web interface within 30 seconds of powering on, using default
IP address 169.254.1.1.
5
Select menu option Configuration, LAN Configuration.
6
Obtain the correct IP address of the unit from the LAN Configuration
page.
Rebooting the unit
To reboot the ODU select menu option Reboot PTP 250. The Reboot Wireless Unit
page is displayed (Figure 7-14). Select Reboot PTP 250 to confirm.
Figu
re 7-14 Reboot Wireless Unit page