PTP 250 User Guide Grounding and lightning protection
phn-2182_002v000
May 2011
2-15
In high lightning prone geographical areas, additional ground kits should be
installed at spacing between 15 to 22 m (50 to 75 ft
). This is especially important
on towers taller than 45 m (150 ft).
A schematic example of a mast or tower installation is shown in Figure 2-3.
Figure 2-3 Grounding and lightning protection on mast or tower
LPU
Tower
ground bar
External
ground bar
Master
ground bar
Ground ring
Outdoor CAT5e cable: gel-filled,
shielded with copper-plated steel
First point of contact with tower
Mid-point of tower
Bottom of tower
CAT5e cable: foil or braid screened,
with screened connectors
PoE Injector
Equipment building
Network
switch
ODU
PTP 250 ground cable
Tower/building ground system