User's Guide
Table Of Contents
- PTP 500 Series User Guide
- Copyright Information
- Disclaimer
- Contents
- List of Figures
- List of Tables
- List of Equations
- 1 About This User Guide
- 2 Product Description
- 2.1 Product Function
- 2.2 Typical Deployment
- 2.3 Frequency Variants
- 2.4 Other Product Variants
- 2.5 Network Connection
- 2.6 Outdoor Unit (ODU)
- 2.7 PIDU Plus PTP 300/500/600 Series
- 2.8 Redundancy and Alternative Powering Configurations
- 2.9 Remote LEDs and Recovery Switch
- 2.10 Cables and Connectors
- 2.11 PTP and Lightning Protection
- 2.12 Mounting Brackets
- 3 Product Features
- 4 Planning Considerations
- 5 Lightning Protection
- 6 Installation
- 6.1 Installation Support
- 6.2 Legal Disclaimer
- 6.3 Preparation
- 6.4 Mounting the ODUs
- 6.5 Connecting Up
- 6.5.1 Preparing the PIDU Plus To ODU Cable
- 6.5.2 Making the Connections at the ODU
- 6.5.3 Making the PIDU Plus Connection At The ODU
- 6.5.4 Routing the Cable
- 6.5.5 Fitting a Lightning Protection Unit
- 6.5.6 Grounding the Installation
- 6.5.7 Making the ODU Connection at the PIDU Plus
- 6.5.8 Making the Network Connection at the PIDU Plus
- 6.5.9 Mounting the PIDU Plus
- 6.5.10 Powering Up
- 6.6 Establishing a Radio Link
- 7 Web Page Reference
- 7.1 Menu Navigation Bar
- 7.2 Home (System Summary)
- 7.3 System Status
- 7.4 System Administration
- 7.5 Configuration
- 7.6 Statistics
- 7.7 Installation Wizard
- 7.8 Software Upgrade
- 7.9 Spectrum Management
- 7.9.1 Wireless Channels
- 7.9.2 Spectrum Management Measurements
- 7.9.3 Measurement Analysis
- 7.9.4 The Spectrum Management Master / Slave Relationship
- 7.9.5 Spectrum Management Configuration
- 7.9.6 Barring Channels
- 7.9.7 Master and Slave Channel Spectrum Graphics
- 7.9.8 Active Channel History
- 7.9.9 Viewing Historic Spectrum Management Metrics
- 7.9.10 Spectrum Management (Fixed Frequency)
- 7.9.11 Spectrum Management Control with Radar Avoidance
- 7.10 Remote Management
- 7.10.1 Control Access to HTTP Interface
- 7.10.2 Control Access to Telnet Interface
- 7.10.3 SNMP (Simple Network Management Protocol)
- 7.10.4 Supported Management Information Bases (MIBS)
- 7.10.5 Diagnostics Alarms
- 7.10.6 SNMP Configuration
- 7.10.7 SMTP (Simple Mail Transport Protocol)
- 7.10.8 SNTP (Simple Network Time Protocol)
- 7.10.9 Setting the clock
- 7.11 Diagnostics Plotter
- 7.12 Change Password
- 7.13 License Key
- 7.14 Properties
- 7.15 Reboot
- 8 Recovery Mode
- 9 Troubleshooting (Fault Finding)
- 10 Connectorized PTP 500 Series Bridge
- 10.1 Product Description
- 10.2 Software/Features
- 10.3 Deployment Considerations
- 10.4 Link Budget
- 10.5 Regulatory Issues with Connectorized Units
- 10.6 Antenna Choices
- 10.7 Installation
- 10.7.1 Cables and Connectors
- 10.7.2 Tools
- 10.7.3 Miscellaneous supplies
- 10.7.4 Mounting the Connectorized PTP 500 Series Bridge
- 10.7.5 Mounting the antennas
- 10.7.6 Alignment Process
- 10.7.7 Aligning Dual Polar Antennas
- 10.7.8 Aligning Separate Antennas
- 10.7.9 Completing the Installation
- 10.7.10 Antenna Cable Fixing
- 10.7.11 Antenna Connection Weatherproofing
- 10.8 Additional Lightning Protection
- 11 E1/T1 Installation Guide
- 12 Data Rate Calculations
- 13 AES Encryption
- 14 Remote Software Upgrade by TFTP
- 15 Legal Notices
- 15.1 Motorola Inc. End User License Agreement
- 15.1.1 Definitions
- 15.1.2 Grant of License
- 15.1.3 Conditions of Use
- 15.1.4 Title; Restrictions
- 15.1.5 Confidentiality
- 15.1.6 Right to Use Motorola’s Name
- 15.1.7 Transfer
- 15.1.8 Updates
- 15.1.9 Maintenance
- 15.1.10 Disclaimer
- 15.1.11 Limitation of Liability
- 15.1.12 U.S. Government
- 15.1.13 Term of License
- 15.1.14 Governing Law
- 15.1.15 Assignment
- 15.1.16 Survival of Provisions
- 15.1.17 Entire Agreement
- 15.1.18 Third Party Software
- 15.2 Hardware Warranty in U.S.
- 15.3 Limit of Liability
- 15.1 Motorola Inc. End User License Agreement
- 16 PTP 500 Reference Information
- 16.1 PTP 500 General Reference Information
- 16.2 PTP 54500 Reference Information
- 16.2.1 PTP 54500 Examples of Regulatory Limits
- 16.2.2 PTP 54500 Licenses and Region Codes
- 16.2.3 PTP 54500 Regulatory Compliance
- 16.2.4 PTP 54500 Radio System Specifications
- 16.2.5 PTP 54500 Emissions and Radio Certifications
- 16.2.6 PTP 54500 Available Spectrum Settings
- 16.2.7 PTP 54500 System Threshold, Output Power and Link Loss
- 16.2.8 PTP 54500 FCC Antenna Restrictions
- 16.3 PTP 58500 Reference Information
- 16.3.1 PTP 58500 Examples of Regulatory Limits
- 16.3.2 PTP 58500 Licenses and Region Codes
- 16.3.3 PTP 58500 Regulatory Compliance
- 16.3.4 PTP 58500 Radio System Specifications
- 16.3.5 PTP 58500 Emissions and Radio Certifications
- 16.3.6 PTP 58500 Available Spectrum Settings
- 16.3.7 PTP 58500 System Threshold, Output Power and Link Loss
- 16.3.8 PTP 58500 FCC Antenna Restrictions
- 17 FAQs
- 18 Glossary
7 Web Page Reference
96
7.5.4 Save and Restore
The save and restore feature of a PTP 500 Series Bridge allows the system administrator to
backup the operation configuration of the wireless unit. It is recommended that this facility is
used immediately after a successful PTP 500 Series Bridge installation or prior to any
software upgrade. In the unlikely event that a unit has to be replaced in the field, the
replacement unit can be reconfigured by simply playing back the saved configuration file.
7.5.4.1 Save Configuration File
To save the configuration file click on the ‘Save Configuration File’ button (Figure 47) and
save the conf
iguration file (.cfg) to the hard drive of your computer.
Figure 47 - Save and Restore Configuration Page
The configuration file format is MAC-mm-mm-mm_IP-iii-iii-iii-iii.cfg, where mm and iii are
the lower 3 bytes of the MAC address and the unit IP address respectively.
NOTE
There is a feature of Internet Explorer (all versions) that looks at the content of any
downloadable file and decides whether to treat the file as ASCII or binary. As a result
of this feature, Internet Explorer always treats the configuration file as ASCII and
attempts to display it instead of downloading it. Firefox (all versions) makes no such
assumption.