Tx FIFO Drops
Total number frames dropped due to lack of capacity in the transmit buffer, for example when
the PTP 500 Series bridge is connected to the local Ethernet at a connection speed of less
than 100 Mbps (Ethernet interface only).
Rx & Tx Frames Q0…Q7
Total number of received or transmitted frames for each Traffic Class (Q0 to Q7).
Rx & Tx Pause Frames
Total number of received or transmitted pause frames (Ethernet interface only).
Packets To Internal Stack
The total number of good packets the bridge has transmitted to the internal stack.
Packets From Internal Stack
The total number of good packets the bridge has received from the internal stack
Packets Ignored By Internal Stack
The total number of bad packets the bridge has transmitted to the internal stack.
Statistics Page Refresh Period
The statistics page refreshes automatically according to the setting entered here (in seconds).
7.7 Installation Wizard
There follows a description of the installation wizard pages along with their use during the
installation configuration process. The actual installation process is described in Section 7.7.2
Manual Configur”.
NOTE
This section assumes that the integrated PTP 500 is being installed. If the
connectorized variant is being installed, refer to Section 10.2 “Software/Features” for
details of the
additional functionality that must be configured.
7.7.1 Factory Configuration
All wireless links are shipped as paired units. They are pre-configured at the factory so that
they can be installed without the user supplying any configuration. Each wireless link is
shipped with a deployment guide. Attached to the deployment guide is a summary of the pre-
configured configuration data. Table 13 shows a sample link configuration. The values in
red
type have been committed to the wireless unit’s non-volatile storage.