10.7.3 Miscellaneous supplies
The following miscellaneous supplies will be required:
Cable ties, cable cleats – for securing cables
Self-amalgamating tape – to weatherproof the RF connectors
PVC tape – for additional protection of the RF connectors and securing cables
10.7.4 Mounting the Connectorized PTP 500 Series Bridge
A Connectorized PTP 500 Series bridge is shipped with the same bracket as supplied with an
Integrated unit. Details on the use of this bracket can be found in Section 2.12 “Mounting
Bracket
s”. The PTP 500 Series Bridge should be mounted in a position that gives it maximum
protection from the elements, but still allows easy access for making off the various
connections and applying the recommended weatherproofing.
When using dual polar antennas the Connectorized PTP 500 Series bridge should be
mounted in such a position as to minimize the cable length, keeping losses to a minimum,
taking into account the minimum cable lengths required by the FCC regulations, see Section
16.3.8 “PTP 58500 FCC Antenna Restrictions”.
Whe
n using separate antennas the Connectorized PTP 500 Series Bridge should be mounted
in such a position as to minimize both cable runs between the unit and the antennas. It is not
necessary to mount the Connectorized PTP 500 Series Bridge at the mid point between the
antennas.
10.7.5 Mounting the antennas
The Antennas should be mounted according to the manufacturer’s instructions. Actual
antenna position will depend on the available mounting positions and link requirements. It
may be necessary to mount the antennas 20m apart or at a certain distance from the ground
to get the desired results.