User's Guide

Table Of Contents
2 Product Description
23
2.9 Remote LEDs and Recovery Switch
The PIDU Plus provides a facility to connect remote LEDs and Recovery switch allowing the
PIDU Plus to be mounted inside an enclosure. At the left hand end of the PIDU Plus under
the ODU connection cover can be found a PCB header and three jumpers. Jumpers J906 and
J907 should be removed and connection to the remote LEDs and Recovery switch made to
J908 as shown in Figure 9.
Figure 9 - Re
mote LED and Recovery Switch Wiring
2.10 Cables and Connectors
The cable used to connect the PIDU Plus to the ODU can be any standard CAT5e type
provided that it is UV resistant and suitable for outdoor deployment. Motorola recommends
that cables to the specification below be used:
Cable: Superior Essex BBDGE CAT 5e
Connector Type: Tyco, 5-569278
Gland: Motorola WB1811
CAUTION
Failure to use the recommended (or equivalent) standard of cable may invalidate the
system’s safety certification.