6.4 Mounting the ODUs
6.4.1 Mounting Bracket
The ODU is pre-fitted with a mounting bracket (designed to ease installation) and an earth bonding
lead (Figure 18).
Figure 18 –
ODU with Mounting Bracket and Earth Bonding Lead
6.4.1.1 Safety Precautions When Mounting the ODU
WARNING
To prevent failure of the assembly, observe the precautions listed below when
mounting the ODU.
The following safety precautions must be taken when mounting the ODU:
Do not remove the pre-fitted mounting bracket from the ODU.
Do not mount the ODU on poles with diameter less than 50mm (2”) or greater than 75mm
(3”). The ODU mounting bracket is designed to work only with poles with diameter in the
50 mm (2”) to 75 mm (3”) range.
Do not over-tighten the bolts.