6 Installation
66
CAUTION
Do not dress the RJ45 cables too tightly, as this may make the connections
unreliable. Figure 32 shoes the correct and incorrect ways to dress RJ45 cables
whe
n connected to the PIDU Plus.
Figure 32 - Correct and Incorrect RJ45 Cable Dressing
CAUTION
The PIDU Plus is not waterproof and should be mounted away from sources of
moisture. If mounted outdoors, the unit should be mounted in a rain proof enclosure,
preferably ventilated.
It is also recommended that you fit a drip loop on the PIDU Plus to ODU cable to ensure that
any moisture that runs down the cable into the cabinet or enclosure cannot enter the PIDU
Plus. This is shown in Figure 33. The network connection and mains cable should be treated
in the sam
e way if there is a risk that they can carry moisture to the PIDU Plus.