Should it be necessary to disconnect the IDU to ODU cable at the ODU this can be achieved
by removing the weather proofing gland and depressing the RJ45 locking tab with a small
screwdriver as shown below:
Figure 9 Disconnecting the ODU
Warning: Ensure that power is removed from the system at the IDU to prevent damage to the
ODU whilst making or breaking the connection.
5.7.3 Routing the Cable
After connecting the cable to the ODU it can be routed and secured using standard cable
routing and securing techniques. When the cable is in place it can then be cut to the desired
length at the IDU prior to connection to the IDU.
5.7.4 Fitting A Surge Arrestor
If you have opted to fit a Surge Arrestor, this should be installed by following the manufacturers
instruction. For recommended types see Section 9 “Lightning Protection”
5.7.5
Grounding The Installation
The OS-Gemini Outdoor unit must be properly grounded to protect against power surges. It is
the user’s responsibility to install the equipment in accordance with Section 810 of the National
Electric Code, ANSI/NFPA No.70-1984 or Section 54 of the Canadian Electrical Code. These
codes describe correct installation procedures for grounding the outdoor unit, mast, lead-in wire
and discharge unit, size of grounding conductors and connection requirements for grounding
electrodes. It is recommended that installation of the outdoor unit be contracted to a
professional installer. See Section 9 “Lightning Protection” for recommended grounding kits.