User's Manual Part 1

Table Of Contents
30
The master unit can take between 10 seconds in 0-5km mode to 60 seconds in 0-130km mode
to determine the range of the link being installed. The Master unit will remain in the Scanning
state until the range of the link has been established. The Master unit will only move to the
Synchronized state when the range of the link has been established.
If at the end of the ranging period the Registered state is not achieved due to interference or
other reasons, the Master unit will retry twice more on the same channel before moving to
another available channel. Should this occur it might take a number of minutes to establish a
link in the Registered state.
The Slave unit does not have a ranging process. The slave unit will change to the
Synchronized state as soon as the wanted signal is demodulated.
When the alignment process is complete the installer MUST REMEMBER TO DISARM BOTH
UNITS in the link as described in section 6.3.3. This is necessary for the following:
Turn off audible alignment aid.
Enable Adaptive Modulation
Fully enable Dynamic Frequency Selection
Clear unwanted installation information from the various systems statistics
Store the link range for fast link acquisition on link drop