User's Manual

34
6.2 Systems Status Page
This page displays the current system status. This page will automatically refresh after a user
defined refresh period. A field is provided to enter the required refresh period. Buttons are
provided to update the refresh period and reset the displayed counters. Refresh can be forced by
using the browsers refresh button.
Figure 16 Status Page
In the section“Equipment” there are various status displayed. The “Country Variant” is depen-
dant upon the software load. The “Link Name” and “Link Location” are attributes which can
be set using the “System Administration” page. Software and Hardware version numbers are
provided as well as the “Elapsed Time Indicator” providing the run time since the last reset.
In the section “Ethernet / Internet” the status of the Ethernet link is provided. The IP address is
that of the web pages and is set on installation or by use of the “System Configuration”. The
SMTP settings can be adjusted on the SMTP page. The page can be automatically refreshed by
the use of the “Refresh this page every... box and pressing the “Update Page Refresh Period”
button.
The section on “Wireless” gives the status of the wireless link. The “Target Modulation Mode”,
Transmit Power Control and Maximum Transmit Power are controlled on the “System Configu-
ration” Page. Transmit and Receive Power, Vector error and Link Loss are displayed Maximum,
Mean and Minimum for the last complete hour. The DFS status is given along with the Active
and available channels. Finally the Radio Range is given and the average bit rate.