User's Manual

8
Figure 3 OS-Gemini Indoor Unit (IDU)
Reset Button Depression
Action
Momentary This is the same as a power cycle. It simply restarts the
unit using the same configuration and software as before.
More than 10 secs This resets the configuration to factory defaults. All
parameters will need to be reentered including the web
page which will have returned to 10.10.10.10.
While connecting power for
more than 15 secs after power
is applied
This resets to factory defaults including to the initial
software load.
Table 1 Reset actions
1.3.4 Cables and Connectors
The cable used to connect the IDU to the ODU can be any standard CAT 5 type provided that it is
suitable for outdoor deployment. Orthogon Systems recommends that cables to the specification
below are used.
NEC/CEC: CMR(ETL) C(ETL) 75C SUN RES OIL RES II