User's Manual

29
5.5.2.3 Routing the Cable
After connecting the cable to the ODU it can be routed and secured using standard cable routing
and securing techniques. When the cable is in place it can then be cut to the desired length at the
IDU prior to connection to the IDU.
5.5.2.4 Fitting A Surge Arrestor
If you have opted to fit a Surge Arrestor, this should be installed by following the manufacturers
instruction.
5.5.2.5 Grounding The Installation
The Gemini 5810 Outdoor unit must be properly grounded to protect against power surges. It is
the user’s responsibility to install the equipment in accordance with Section 810 of the National
Electric Code, ANSI/NFPA No.70-1984 or Section 54 of the Canadian Electrical Code. These
codes describe correct installation procedures for grounding the outdoor unit, mast, lead-in wire
and discharge unit, size of grounding conductors and connection requirements for grounding
electrodes. It is recommended that installation of the outdoor unit be contracted to a professional
installer.
5.5.2.6 Making the Connection At The IDU
The ODU is connected to the IDU by means of a concealed RJ45 connector. The RJ45 connection
has been placed inside the IDU to prevent the user inadvertently plugging other equipment into
the ODU RJ45 socket.
Warning: Plugging other equipment into the ODU RJ45 socket may damage the equipment due
to the non-standard Power-over-Ethernet techniques employed.