User's Guide

Table Of Contents
Chapter 3: System Hardware
39
DC power feed
The maximum length for supplying power over a CAT6A Ethernet cable is shown in " Maximum cable length for DC power"
below.
Table 17: Maximum cable length for DC power
Radio PSU PoE enabled Maximum cable length 14 AWG Maximum cable length 16 AWG
V5000 60 W - 660 m 410 m
25 W
Not supported
100 W - 660 m 410 m
25 W 360 m 220 m
Outdoor copper Ethernet cable
Select an outdoor rated CAT6A cable, ready terminated with RJ45 connectors in the one of the following lengths:
l
25 m
l
50 m
l
100 m
Alternatively, terminate bulk CAT6A cable with RJ45 connectors at a length to suit each installation.
Table 18: Terminated Ethernet cable part numbers
Cambium Description Cambium part number
CAT6A Outdoor Cable, 305m N000082L172B
RJ45 Connector for CAT6A Cable N000082L174B
CAT6A Outdoor Cable, 100m N000000L155A
Radio PSU PoE enabled Maximum cable length 14 AWG Maximum cable length 16 AWG
V3000 60 W - 780 m 490 m
25 W 140 m 90 m
100 W - 780 m 490 m
25 W 390 m 250 m
Attention
Always use CAT6A or better cable that has an overall copper braid shield, outdoor rated, with UV-resistant
sheath