i-SERIES iD4 USER MANUAL ADVANCED AMPLIFIERS INFORMATION FOR USE iD4 i-SERIES TDA302USERGBE Revision E, 2014-02-11 Please visit our website www.camcoaudio.com for the latest version of this user manual. Please note that the leading version of CAMCO manuals is always the English one. © Copyright 2013 by CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen Fischpicke 5, D-57482 Wenden, Germany Telephone +49 (0) 2762 / 408-0 P.
i-SERIES IMPORTANT SAFETY INSTRUCTIONS ADVANCED AMPLIFIERS P.2 IMPORTANT SAFETY INSTRUCTIONS 1. General The amplifier may only be used in accordance with the information provided in the user manual. Before and during the usage of the amplifier please ensure that all recommendations, especially the safety recommendations as detailed in the user manual, are adhered to. The iD4 amplifier is designed for the amplification of pulsed audio signals.
i-SERIES IMPORTANT SAFETY INSTRUCTIONS ADVANCED AMPLIFIERS 10. Connections When you connect the amplifier to other equipment, turn off the power and unplug all of the equipment from the supply source. Failure to do so may cause an electric shock and serious personal injury. Read the user manual of the other equipment carefully and follow the instructions when making the connections. 11.
i-SERIES EXPLANATION OF SYMBOLS ADVANCED AMPLIFIERS EXPLANATION OF SYMBOLS CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION – HIGH VOLTAGE HAZARDS EXIST WITHIN THIS PRODUCT. REFER ALL SERVICING TO AUTHORIZED PERSONNEL. THE LIGHTNING FLASH WITH ARROW HEAD SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF UNINSULATED DANGEROUS VOLTAGE WITHIN THE PRODUCT’S ENCLOSURE.
i-SERIES EC DECLARATION OF CONFORMITY ADVANCED AMPLIFIERS EC DECLARATION OF COMFORMITY EC Declaration of Conformity in accordance to EC Directives: Electromagnetic compatibility (Council Directive 2004/108/EC); low-voltage electrical equipment (Council Directive 2006/95/EC) Manufacturer´s Name: CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen Manufacturer´s Address: Fischpicke 5, D-57482 Wenden, Germany Declares that the product with the model name: CAMCO Power amplifier iD
i-SERIES CONTENTS ADVANCED AMPLIFIERS P.6 Important Safety Instructions P.2 Explanation of Symbols P.4 EC Declaration of Comformity P.5 1. Welcome to CAMCO P.7 1.1 Unpacking P.7 2. The Amplifier P.8 2.1 iD4 – The Front P.9 2.2 iD4 – The Rear P.9 3. Installation P.10 3.1 Mains Supply P.10 3.2 On / Off Switch P.10 3.3 Mounting P.11 3.4 Cooling P.11 3.5 Signal Inputs P.12 3.5.1 Analog Input P.12 3.5.2 AES Input P.12 3.6 Remote Control / Network Input P.12 3.7 Power Outputs P.12 3.7.1 SPEAKON® Connection P.
i-SERIES 1 WELCOME ADVANCED AMPLIFIERS 1. Welcome to CAMCO Thank you for choosing CAMCO products. You are now the proud owner of a very advanced CAMCO Amplifier. The technologies used in your amplifier are of the latest generation and designs delivering a far reaching set of results across all functions. The amplifier has been designed to be incorporated into a professional speaker system and is suitable for use across all applications from Touring Live Sound to Fixed Installations.
i-SERIES 2.
i-SERIES ADVANCED AMPLIFIERS 2 THE AMPLIFIER 2.1 iD4 – The Front Signal-LEDs Clip-LEDs Character LCD Channel buttons Item buttons Menu buttons Rotary encoder with push button Removable air filter system Cooling air inlet vents On/Off switch 2.
i-SERIES 3 INSTALLATION ADVANCED AMPLIFIERS 3. Installation 3.1 Mains Supply When mounting or connecting the amp always disconnect it from mains. Only connect the iD4 amplifier to an appropriate AC circuit and outlet, according to the requirements indicated in the second line on the rating plate.
i-SERIES 7,50 mm 3.3 Mounting Use four screws and washers when mounting the amplifier to the front rack rails. For mobile use, the amplifier should also be secured using the 19” mounting elements on the rear panel. 88,10 mm 10,50 mm Note that continous high power draw at low load impedance (equal or less than approx. 2,7 Ω) can drive the amplifier into thermal limitation.
i-SERIES 3 INSTALLATION ADVANCED AMPLIFIERS 3.5 Signal Inputs 3.7 Power Outputs 3.5.1 Analog Input XLR: Pin 1 = Ground Pin 2 = Hot (inphase) Pin 3 = Cold (out of phase) 3.7.1 SPEAKON® Connection Both SPEAKON® connectors are connected to channel 1 and channel 2 outputs. The pin configuration of the SPEAKON connectors is as follows: Always use symmetrical (balanced) shielded cable to connect the amplifier. 3.5.
i-SERIES 3 INSTALLATION ADVANCED AMPLIFIERS 3.7.2 Dual Channel Operation Two fully independent amplifier channels (“Stereo” – normal operating mode). iD4 In 1 In 2 Zmin = 2 Ω for Dual Channel operation 3.7.3 Mono Bridge Operation One-channel mono bridged operation. iD4 In 1 180° In 2 Zmin = 4 Ω for Mono Bridge operation In this mode the channel 2 amplifier stage processes the identical input signal than channel 1, but with reversed phase. The channel 2 input signal is not used / ignored.
i-SERIES 4 OPERATION ADVANCED AMPLIFIERS 4. Operation cates heavy clipping. These LED’s exclusively indicate hardware clipping of the power amplifier stage. Possible internal DSP limitation and compression is not indicated here. 4.1 User Interface Elements l NOTE This chapter only describes the basic user interface operation and functions.
i-SERIES 4 OPERATION ADVANCED AMPLIFIERS à Configure the peak limiter Limiter Compressor à Configure the compressor à Selects if Input 1 & 2, Input 3 & 4 or Output 1 & 2 Link shall be linked All settings and selections are done through the rotary encoder. Changes will take effect immediately. 4.1.5 MENU Buttons The left (3) MENU button will always act as an ESCAPE / EXIT button.
i-SERIES 4 OPERATION ADVANCED AMPLIFIERS 4.4 Power Amp Protection Systems 4.4.1 Clip Limiter / Underimpedance Limiter The DSP section of the iD4 offers various limiter and compressor settings, both on the signal inputs and on the signal outputs. Those limiters and compressors can be adjusted and even switched off completely if desired. Disabling the limters is done by setting the thresholds to their highest values. But in case the amplifier is driven into hardware clip (i. e.
i-SERIES 4 OPERATION ADVANCED AMPLIFIERS P.17 4.5.5 Fuse Protection When driving the iD4 at very high output levels over a longer period of time (i.e. several seconds and minutes) the average mains current draw can become very high. In such situations, the FuseProtect limiter will reduce the output signal in order to prevent the external mains breaker from tripping.
i-SERIES 4 OPERATION ADVANCED AMPLIFIERS 4.8 Filter Cleaning The air intake on the front of your iD4 amplifier is fitted with a removable filter system. If the filter becomes clogged, the unit will not cool as efficiently as it should and may result in reduced output levels. iD4 Filter Assembly Foam filter Front frame Screw ! WARNING! Turn off and disconnect the amplifier from the mains before removing the front frame.
i-SERIES 5 TROUBLESHOOTING ADVANCED AMPLIFIERS 5. Troubleshooting 5.1 Problem: No reaction when switching the amplifier on If nothing happens when switching the amplifier on (i.e. the display stays totally dark, no message inside the display), please check following points: Check mains cable and plug Confirm that the AC outlet works by plugging in any other device 5.
i-SERIES 6 SPECIFICATION ADVANCED AMPLIFIERS 6.
i-SERIES 6 SPECIFICATION ADVANCED AMPLIFIERS Frequency response @ 4 Ω load with 120 W ouptut power THD+N over frequency @ 4 Ω load with 120 W output power Damping factor 8 Ω load, 1 kHz and below Input impedance Amplifier gain Maximum analogue differential input level Level attenuation Minimum loudspeaker load impedance Lower values are safe, but out of specification. No performance guarantees can be given when driving lower impedances than specified.
i-SERIES 6 SPECIFICATION ADVANCED AMPLIFIERS Latency Digital inputs AC mains * Approximative mains voltage range where the amplifier can be used. Amplifier output power performance will decrease with lower mains voltages than the rated 230 V / 220 V / 120 V and slightly increase with higher mains voltages. Operating temperature Dimensions (W × H × D) Net weight Shipping dimensions (W × H × D) Shipping weight Min.
i-SERIES 7. Typical Performance Diagrams 1 +1 +0,5 0 -0,5 0,1 -1,5 % dBr -1 -2 0,01 -2,5 -3 -3,5 10 100 1k 10k 20k 50k -50 -40 Hz Figure 7.1 Gain vs. frequency, 120 W output power (Measurement of a typical performance @ 2 Ω & 4 Ω) -30 dBu -20 -10 0 4 Figure 7.3 THD @ 1 kHz vs. input level @ 2 Ω load (32 dB amplifier gain) (Measurement of a typical performance of Ch 1 & Ch 2) 1 1 0,1 0,1 % 0,01 0,01 0,001 -60 0,001 -50 -40 -30 -20 -10 0 dBu Figure 7.2 THD @ 1 kHz vs.
i-SERIES 0 0 -10 -20 -20 -30 dBr dBr -40 -60 -60 -100 -70 -120 -80 10 100 1k 10k 10 20k 100 Hz 1k 10k 20k Hz Figure 7.5 Channel separation vs. frequency @ 120 W / 4 Ω (Measurement of a typical performance of Ch 1 à Ch 2 & Ch 2 à Ch 1) Figure 7.7 Common mode rejection ratio vs. frequency (Measurement of a typical performance of Ch 1 & Ch 2) 10 100 10 1 1 100 m V 0,1 10 m 1m 100 µ 0,01 10 µ 0,001 -60 1µ -50 -40 -30 -20 -10 dBu Figure 7.6 DIM100 vs.
i-SERIES P.25 1000 100 m 800 damping factor 300 m Ω 7 TYPICAL PERFORMANCE DIAGRAMS ADVANCED AMPLIFIERS 10 m 600 400 200 0 2m 20 100 1k Hz Figure 7.9 Output impedance vs. frequency @ 1 Amp RMS injected current equivalent 11 mΩ + 2,1 µH (Measurement of a typical performance of Ch 1 & Ch 2) USER MANUAL i - SERIES 10k 20k 10 100 1k 10k 20k Hz Figure 7.
i-SERIES 8. Unit Conversion Equations and Lookup Table 8.1 Unit Conversion Equations Unit conversion VRMS à dBu VRMS à dBV dBu à VRMS dBV à VRMS 8Ω VRMS à VPeak 2Ω VRMS à Output power 8.
i-SERIES 9 WARRANTY INFORMATION ADVANCED AMPLIFIERS P.27 9. Warranty Information 9.1 Summary of Warranty CAMCO guarantees the iD4 amplifier to be free from defective material and / or workmanship for a period of six (6) years from the date of sale. When a defect occurs under normal installation and use, CAMCO will repair the product under this warranty. In this event, please return the amplifier to your dealer / distributor together with a copy of your sales receipt as proof of purchase. 9.
i-SERIES 10 SERVICE INFORMATION ADVANCED AMPLIFIERS 10.
i-SERIES 11 MAINTENANCE INFORMATION / 12 DECOMISSIONING ADVANCED AMPLIFIERS P.29 11. Maintenance Information Cleaning and servicing the inside of the amplifier must never be carried out by unqualified personnel. The amplifier must never be opened by unqualified personnel. Cleaning and servicing work on the inside of the amplifier must only be carried out by qualified personnel.
i-SERIES 13 COMPANY INFORMATION ADVANCED AMPLIFIERS P.30 13. Company Information Mailing Address: CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen Fischpicke 5 57482 Wenden Germany Telephone: +49 (0) 27 62 / 408 - 0 Facsimile: +49 (0) 27 62 / 408 - 10 Internet: www.camcoaudio.com E-Mail: postmaster@camcoaudio.
i-SERIES 14 CHANGES MADE TO THE AMPLIFIER / NOTICES ADVANCED AMPLIFIERS P.31 14.
i-SERIES 14 CHANGES MADE TO THE AMPLIFIER / NOTICES ADVANCED AMPLIFIERS P.