User Manual

VORTEX
SILVER SERIES
465,0 mm
442,0 mm
483,0 mm
424,5 mm
452,5 mm
76,2 mm
88,1 mm
10,5 mm
7,5 mm
440,5 mm
USER MANUAL
VORTEX SILVER SERIES V8
P.10
2.5 Factory settings
V8 amplifiers are delivered with the following factory settings
Power Status Amplifier is switched Off
Input Selection Analog
AmpGain 32 dB
Output Mode Dual Channel
Mute Both channels active (unmuted)
Level Attenuator 0 dB both channels
Clip Limiter Off
DSP Off
Lock Device Unlocked
Ethernet Settings 192.168.1.20
Ethernet Mask 255.255.255.0
Ethernet Gateway 192.168.1.200
U
man
IP 192.168.20.1
U
man
Mask 255.255.255.0
U
man
Gateway 192.168.20.1
FuseProtect level 24 A
In the settings menu there are three options to restore the original factory
settings.
1. The reset "Settings" option will restore all amplifier parameters and a
reboot of the amplifier will take place. Note that this type of reset is also
done at the end of each a firmware update process.
2. The "Settings+IP" option will do the same but additionally also restore
the Ethernet and U
man
network IP settings to the above values.
3. The third option "Settings+IP+Presets" will additionally delete all previ-
ously stored or downloaded DSP presets, leaving the amplifier with a
blank (empty) preset memory. So please don’t forget to make a backup
of all your user defined presets before choosing this option.
3.1 Mounting
Use four screws and washers when mounting the amplifier to the front rack
rails. For mobile use, the amplifier should also be secured using the 19”
mounting elements on the rear panel.
2 THE AMPLIFIER / 3 INSTALLATION